B200 series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Type | B200-10A | B200-20A | B200-30A | B200-40A | Unit |
Rated current(Ipn) | 10 | 20 | 30 | 40 | A |
Measure range(Ip) | 20 | 40 | 60 | 80 | A |
Turns ratio(Np/Ns) | 1:1000 | 1:1000 | 1:1000 | 1:1600 | T |
Internal resister | 100±0.1% | 50±0.1% | 50±0.1% | 50±0.1% | Ω |
Rated output | @Ip=±Ipn ±1±0.5% | V | |||
Supply voltage | +5V | V | |||
Power Consumption | ≤20+ IpX(Np/Ns) | mA | |||
Zero voltage | @Ip=0 +2.5±0.5% | V | |||
Zero voltage drift | @ -40~+85℃ ≤±0.5 | mV /℃ | |||
Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||
Total precision | ≤±0.7 | % | |||
di/dt accurately followed | >50 | A /μS | |||
Response time | @100A/μ S,10%-90% ≤500 | ns | |||
Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV | |||
Bandwidth | @ -1db DC~200 | KHZ |
Dimensions
Mechanical dimension(for reference only) | Note |
1.All dimensions are in mm. 2. General tolerance ±1mm. 3. Elucidation: 1:+5V 2:OV 3:V0UT |
|
General date | Value | Unit |
Operating temperature(TA) | -40 to +85 | ℃ |
Storage temperature(TS) | -40 to +125 | ℃ |
Mass(approx) (M) | 10 | g |
Accuracy test
Pulse current signal response characteristic | Effects of impulse noise | ||
( Input signal ) ( Output signal ) |
( Output voltage ) |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
You can get a beautiful gift by interacting with us in the following ways
HEYI © All Rights Reserved.