B201X series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Type | B201X-10A | B201X-20A | B201X-30A | B201X-50A | Unit |
Rated current(Ipn) | 10 | 20 | 30 | 50 | A |
Measure range(Ip) | 20 | 30 | 45 | 75 | A |
Turns ratio(Np/Ns) | 1:1000 | 1:1000 | 1:1000 | 1:1000 | T |
Measure resister | 960±0.1% | 490±0.1% | 306±0.1% | 169±0.1% | Ω |
Rated output | 10 | 20 | 30 | 50 | mA |
Coil resister | 36 | 36 | 36 | 36 | Ω |
Supply voltage | ±12,±15 | V | |||
Power Consumption | ≤20+ IpX(Np/Ns) | mA | |||
Offset current | @Ip=0 ±0.15 | mA | |||
Offset drift | @ -40~+85℃ ≤±0.5 | mA | |||
Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||
Total precision | ≤±0.7 | % | |||
di/dt accurately followed | >50 | A /μS | |||
Response time | @100A/μ S,10%-90% ≤1 | μS | |||
Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV | |||
Bandwidth | @ -1db DC~100 | KHZ |
Dimensions
Mechanical dimension(for reference only) | Note |
1. All dimensions are in mm. 2. General tolerance ±1mm. 3. Elucidation: 1:+15V 2: -15V 3:I0UT 3:NC |
|
General date | Value | Unit |
Operating temperature(TA) | -40 to +85 | ℃ |
Storage temperature(TS) | -40 to +125 | ℃ |
Mass(approx) (M) | 26 | g |
Accuracy test
Pulse current signal response characteristic | Effects of impulse noise | ||
( Input signal ) ( Output signal ) |
( Output voltage ) |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
You can get a beautiful gift by interacting with us in the following ways
HEYI © All Rights Reserved.