D1 series current sensor is a closed loop device based on the principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Type | D1-50A | D1-100A | D1-200A | D1-300A | Unit |
Rated current(Ipn) | ±50 | ±100 | ±200 | ±300 | A |
Measure range(Ip) | 0—±75 | 0—±150 | 0—±300 | 0—±350 | A |
Turns ratio(Np/Ns) | 1:1000 | 1:1000 | 1:2000 | 1:2000 | T |
Measure resister | 0~200 | 0~200 | 0~80 | 0~50 | Ω |
Coil resister | 12.5 | 12.5 | 27.5 | 27.5 | Ω |
Rated output | 50 | 100 | 100 | 150 | mA |
Supply voltage | ±12,±15 | V | |||
Power Consumption | ≤20+IpX(Np/Ns) | mA | |||
Offset current | @Ip=0 ±0.15 | mA | |||
Offset drift | @ -40~+85℃ ≤±0.4 | mA | |||
Linearity | @Ip=0-±Ipn ≤0.1 | %FS | |||
Response time | @50A/μS, 10%-90% ≤1 | μS | |||
Galvanic isolation | @ 50HZ,AC,1min 3 | KV | |||
di/dt | >100 | A/us | |||
Bandwidth | @ -3dB 0~100 | KHZ |
Dimensions
Mechanical dimension(for reference only) | Note |
1. All dimensions are in mm. 2. General tolerance ±1mm. 3. Elucidation: 1:+15V 2:–15V 3:I0UT 4:NC |
|
General date | Value | Unit |
Operating temperature(TA) | -40 to +85 | ℃ |
Storage temperature(TS) | -40 to +125 | ℃ |
Mass(approx) (M) | 43 | g |
Accuracy test
Pulse current signal response characteristic | Effects of impulse noise | ||
( Input signal ) ( Output signal ) |
( Output voltage ) |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000
You can get a beautiful gift by interacting with us in the following ways
HEYI © All Rights Reserved.