K3NT series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
Type | K3NT-30A | K3NT-50A | K3NT-100A | K3NT-150A | K3NT-200A | Unit |
Rated current(Ipn) | ±30 | ±50 | ±100 | ±150 | ±200 | A |
Measure range(Ip) | 0—±60 | 0—±100 | 0—±200 | 0—±300 | 0—±400 | A |
Rated output | @Ip=±Ipn ±1±1% | V | ||||
Zero voltage | @Ip=0 2.5±0.5% | V | ||||
Supply voltage | +5,+12,+15 | V | ||||
Power Consumption | ≤15 | mA | ||||
Zero offset voltage | @Ip=0 ±20 | mV | ||||
Magnetic offset | @Ip=±Ipn-0 ±15 | mV | ||||
Offset drift | @ -40~+85℃ ≤±0.5 | mV/℃ | ||||
Output drift | @ -40~+85℃ ≤±0.5 | mV/℃ | ||||
Linearity | @Ip=0-±Ipn ≤1 | %FS | ||||
Response time | @50A/μS, 10%-90% ≤5 | μs | ||||
Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV |
Dimensions
Mechanical dimension(for reference only) | Note |
1. All dimensions are in mm. 2. General tolerance ±1mm. 3. Elucidation: 1:+5V 2:V 3:V0UT 4:2.5V |
|
General date | Value | Unit |
Operating temperature(TA) | -40 to +85 | ℃ |
Storage temperature(TS) | -40 to +125 | ℃ |
Mass(approx) (M) | 26 | g |
Accuracy test
Pulse current signal response characteristic | Effects of impulse noise | ||
( Input signal ) ( Output signal ) |
( Output voltage ) |
Standards
UL94-V0.
EN60947-1:2004
IEC60950-1:2001
EN50178:1998
SJ 20790-2000